Seismic Assessment of Wanaka motel

Key Services

Our Structural Engineers conducted a detailed seismic assessment for this two-story motel with adjoining office and caretaker’s house. The motel was built in 1996, while the caretaker’s house, originally constructed in 1977, was connected to the motel in 1996. The services we provided included:

  • Desktop Review: We reviewed property files and archived drawings for the building. Additionally, we coordinated with the client to gather more information, such as photographs from previous renovations that revealed the exposed structure.

  • Visual Inspections: We performed an in-depth visual inspection of the building to document its structural features, verify key dimensions, identify areas of deterioration, and pinpoint high-service areas that need to be considered in retrofit designs.

  • Non-Invasive Testing: We used non-invasive techniques to assess the as-built configuration of the building, including:

    • Borescope inspection to examine concealed structural connections.
    • Identification of the reinforcing arrangement in concrete elements using a structural Ground Penetrating Radar (GPR) scanner and rebar scope.
  • Seismic Assessment: We conducted a Detailed Seismic Assessment of both primary and secondary structural elements, confirming the seismic rating of key components and identifying any elements with less than 34% NBS (New Building Standard).