Testing of Screw & Bolt fixings
Key Services
Building King engaged our structural testing team to determine the reliable withdrawal capacity and head pull-through capacity of a range of fixing types.
The project delivery included the following elements:
- Client Workshop
Held an initial meeting with the client to confirm and clarify testing requirements. - Test Setup
Designed and fabricated a customised test setup to suit the client’s needs. - Testing Programme
The programme included:- Withdrawal testing of screws with 31mm embedment into SG8 framing.
- Pull-through testing of screw fixings in 19mm thick weatherboards.
- Monitoring of applied loads and displacement throughout testing.
- Concrete through-bolt testing in sample concrete blocks with a specified MPa rating.
- Repetition for Accuracy
Conducted a minimum of five repeat tests for each fixing type, providing sufficient data to reduce the strength reduction factor (kt) in line with AS/NZS 1170.0 requirements. - Fixings Tested
- Blue Purlin Screw 12G x 50–90mm
- Jolt Screw 8G x 65mm – steel.
- Jolt Screw 8G x 65mm – stainless steel.
- Jolt Screw 8G x 75mm – steel.
- Jolt Screw 8G x 75mm – stainless steel.
- Concrete Through Bolt 12mm x 140mm
- Reporting & Deliverables
Processed the test data and prepared a comprehensive report outlining findings, including the characteristic strength of each fixing type. An engineering standard and typical details were also prepared to support the client’s requirements.