Testing of Screw & Bolt fixings

Screw Pull-out Testing
Bolt in Concrete Testing

Key Services

Building King engaged our structural testing team to determine the reliable withdrawal capacity and head pull-through capacity of a range of fixing types.

The project delivery included the following elements:

  • Client Workshop
    Held an initial meeting with the client to confirm and clarify testing requirements.
  • Test Setup
    Designed and fabricated a customised test setup to suit the client’s needs.
  • Testing Programme
    The programme included:
    • Withdrawal testing of screws with 31mm embedment into SG8 framing.
    • Pull-through testing of screw fixings in 19mm thick weatherboards.
    • Monitoring of applied loads and displacement throughout testing.
    • Concrete through-bolt testing in sample concrete blocks with a specified MPa rating.
  • Repetition for Accuracy
    Conducted a minimum of five repeat tests for each fixing type, providing sufficient data to reduce the strength reduction factor (kt) in line with AS/NZS 1170.0 requirements.
  • Fixings Tested
    • Blue Purlin Screw 12G x 50–90mm
    • Jolt Screw 8G x 65mm – steel.
    • Jolt Screw 8G x 65mm – stainless steel.
    • Jolt Screw 8G x 75mm – steel.
    • Jolt Screw 8G x 75mm – stainless steel.
    • Concrete Through Bolt 12mm x 140mm
  • Reporting & Deliverables
    Processed the test data and prepared a comprehensive report outlining findings, including the characteristic strength of each fixing type. An engineering standard and typical details were also prepared to support the client’s requirements.